跳到正文
arXiv cs.AI· Yixuan Duan, Kexin Geng, Hanwen Xu, Wei Qiu·· 57 分钟前AI 评分44

HERMES:从 H&E 与 mIF 联合推理肿瘤免疫微环境的可解释病理 MLLM

Beyond Final Answers: Interpretable Tumor Immune Microenvironment Reasoning from H&E and mIF

AI 导读

HERMES 是一个 R1 风格的多模态大语言模型,基于同一切片的 H&E 与多重免疫荧光(mIF)配对数据,按临床指南步骤推理肿瘤免疫微环境,并用过程奖励对每一步所述数值进行监督。

正文 · 原文

View PDF HTML (experimental)

Abstract:Readouts of the tumor immune microenvironment (TIME), such as CD8+ T-cell density, intra-epithelial infiltration and the Ki67 index, combine tissue architecture from H&E with cell phenotypes from multiplex immunofluorescence (mIF). Multimodal large language models (MLLMs) could automate these readouts with an explanation, but two gaps remain. Pathology MLLMs read H&E alone, while these readouts need the cell phenotypes that mIF measures. And their reasoning has no step-level truth to be checked against, so R1-style reinforcement learning rewards only the final answer and leaves the reasoning unverified. Same-section H&E and mIF provide what both gaps lack: mIF measures every cell without manual annotation, which gives cell-level ground truth for each step that clinical guidelines prescribe, from delineating a tissue compartment to counting and normalizing the marker-positive cells within it. We therefore present HERMES (H&E-mIF Reasoning with Multimodal Evidence Supervision), an R1-style MLLM that reasons jointly over paired H&E and mIF in guideline steps and is trained with a process reward that checks every stated quantity against this truth. Across four field-level TIME tasks in colorectal cancer, HERMES (4B) reaches an average accuracy of 84.5%, compared with 74.7% for the strongest of twelve proprietary, general, medical and pathology MLLMs, and a higher share of its intermediate quantities is correct than for the strongest open-weight baseline. Without the process reward, reinforcement learning barely improves on supervised fine-tuning (80.0% vs. 78.8%) and fewer stated quantities are correct; editing a decisive stated quantity changes the answer as implied in all 885 test questions. Without retraining, it keeps the highest average accuracy on an external cohort imaged with CODEX (76.4% vs. 67.3%) and on head and neck cancer, a cancer type absent from training (76.7% vs. 72.5%).
Comments: 23 pages, 12 figures, 13 tables
Subjects: Artificial Intelligence (cs.AI); Quantitative Methods (q-bio.QM)
Cite as: arXiv:2611.26794 [cs.AI]
  (or arXiv:2611.26794v1 [cs.AI] for this version)
  https://doi.org/10.48550/arXiv.2611.26794

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Yixuan Duan [view email]
[v1] Thu, 19 Nov 2026 20:36:13 UTC (12,180 KB)

来源:arXiv cs.AI · arxiv.org