跳到正文
arXiv cs.AI· Sezgin Er, Utku Turkbey, Alperen Gur, Omer Faruk Durugol, Suprosanna Shit, Murong Xu, Julia Wolleb, Jiayi Wang, Xiaoliang Wang, Hadrien Reynaud, Teodora Spasojevic, Dong Yang, Andriy Myronenko, Pengfei Guo, Yufan He, Can Zhao, Marc Edgar, Andreas Maier, Michael Moor, Mehmet Kemal Ozdemir, Daguang Xu, Bernhard Kainz, Bjoern Menze, Ibrahim Ethem Hamamci·· 2 小时前AI 评分52

FORA 通用 CT 模型识别 1028 个影像概念并生成 28 种扫描协议报告

Reliable and grounded reporting of any computed tomography scan with FORA

AI 导读

研究团队发布通用 CT 模型 FORA,可识别并空间定位 1028 个分级组织的影像学概念,覆盖 28 种 CT 扫描协议的报告生成。

正文 · 原文

Authors:Sezgin Er, Utku Turkbey, Alperen Gur, Omer Faruk Durugol, Suprosanna Shit, Murong Xu, Julia Wolleb, Jiayi Wang, Xiaoliang Wang, Hadrien Reynaud, Teodora Spasojevic, Dong Yang, Andriy Myronenko, Pengfei Guo, Yufan He, Can Zhao, Marc Edgar, Andreas Maier, Michael Moor, Mehmet Kemal Ozdemir, Daguang Xu, Bernhard Kainz, Bjoern Menze, Ibrahim Ethem Hamamci

View PDF HTML (experimental)

Abstract:Artificial intelligence systems for computed tomography (CT) remain largely restricted to specific anatomical regions, examination types or predefined abnormalities, limiting their ability to provide comprehensive and spatially grounded interpretations. Here we present FORA, a general-purpose CT model that recognizes and spatially localizes 1,028 hierarchically organized radiological concepts and generates reports across the 28 CT protocols represented in our cohort. Trained on 304,962 routine CT examinations supervised by their accompanying reports, FORA learns to localize abnormalities without manually annotated lesions. Its architecture combines multiple-instance learning with an interpretable concept bottleneck that connects spatial evidence, radiological findings and report generation. We first developed and benchmarked the architecture on chest radiographs, achieving state-of-the-art performance, before training a separate model on three-dimensional CT examinations. On 36,619 held-out CT examinations, FORA achieved a macro area under the receiver operating characteristic curve (AUROC) of 0.918 for radiological concept recognition, exceeding the strongest of 18 existing CT models by 0.21. FORA also ranked first on three public benchmarks, outperforming Merlin on its own test set without training on that institution's data (AUROC 0.907 versus 0.826). On independent localization benchmarks for pulmonary emboli, renal masses and rib fractures, FORA's strongest spatial evidence fell within annotated lesions at rates up to 348 times greater than chance. FORA achieved more than threefold higher macro-averaged finding recall than the strongest existing report generator. These results show that a single model can combine broad abnormality recognition, spatial localization and report generation across 12 CT examination types, using routine reports without lesion-level supervision.
Comments: 58 pages, 5 figures, 7 Extended Data figures, 17 Supplementary figures. Code and models: this https URL
Subjects: Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)
ACM classes: I.2.10; I.2.7; I.4.9; J.3
Cite as: arXiv:2611.32823 [cs.CV]
  (or arXiv:2611.32823v1 [cs.CV] for this version)
  https://doi.org/10.48550/arXiv.2611.32823

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Sezgin Er [view email]
[v1] Tue, 24 Nov 2026 15:39:26 UTC (26,359 KB)

来源:arXiv cs.AI · arxiv.org