跳到正文
arXiv cs.AI· Yitian Tang, Yuncheng Zhang, Hualiang Wang, Zuozhu Liu·· 10 小时前AI 评分30

稀疏视角低剂量 CT 重建中的角度插值:位置影响与数据一致性步长缩放

Angular Interpolation in Sparse-View Low-Dose CT Reconstruction: Placement Effects and Data-Consistency Step-Size Scaling

AI 导读

该研究量化了双域网络中角度插值在稀疏视角低剂量 CT 重建不同放置位置的作用。在合成平行束数据上,无参数插值在 60 视角下将无噪声缺失视角 MAE 相对零填充降低 99.7%;DC-DuNet 消融显示正弦图初始化带来 +1.98 dB PSNR,而插值图像基为 -2.16 dB。

正文 · 原文

View PDF HTML (experimental)

Abstract:Dual-domain networks combine projection and image processing for sparse-view low-dose computed tomography (CT). We quantify the contribution of angular interpolation before learning and distinguish its roles in sinogram initialisation and the image residual base. On synthetic parallel-beam data, parameter-free interpolation reduces noise-free missing-view mean absolute error by 99.7% relative to zero filling at 60 views. Full-view filtered back-projection (FBP) of the jointly learned completed sinogram adds 1.27 dB of peak signal-to-noise ratio (PSNR) over interpolated FBP. In a data-consistency dual-domain network (DC-DuNet), a 2x2 configuration ablation controls branch width, depth and training schedule while varying these placements and their associated input channels. After 20 epochs, the PSNR contrasts are +1.98 dB for sinogram initialisation and -2.16 dB for the interpolated image base; the image-base ranking also reverses during training. The sinogram-initialised variant exceeds an image-only U-Net by 0.96 dB at 60 views and 10% dose, and by 1.28 dB on independently generated synthetic data. The U-Net leads at higher view counts and with a shared interpolated image base. Without retraining, the variant retains a 0.12 dB advantage on held-out CHAOS abdominal CT under simulated degradation; the image-base contrast rounds to zero. The implemented projection/backprojection pair has empirical dominant gain of approximately 0.85NK, where N is image-grid width and K acquired view count. These results distinguish interpolation placement from network architecture and support NK normalisation for step calibration.
Comments: 12 pages, 3 figures, 3 tables
Subjects: Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)
Cite as: arXiv:2611.34508 [cs.CV]
  (or arXiv:2611.34508v1 [cs.CV] for this version)
  https://doi.org/10.48550/arXiv.2611.34508

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Yuncheng Zhang [view email]
[v1] Wed, 25 Nov 2026 14:57:39 UTC (275 KB)

来源:arXiv cs.AI · arxiv.org