跳到正文
arXiv cs.AI· Johannes B. Thalhammer, Kacper Og\'orek, Tina Dorosti, Sebastian Peterhansl, Daniel Frey, Zijin Huang, Theresa Hiu, Tobias Lasser, Daniela Pfeiffer, Franz Pfeiffer, Florian Schaff·· 56 分钟前AI 评分38

基于 Diffusion Autoencoder 类条件潜在采样的隐私保护型胸部 CT 合成方法研究

Diagnostically Meaningful, Privacy-aware Synthetic Chest CT via Class-Conditional Latent Sampling in Diffusion Autoencoders

AI 导读

一项研究提出基于 Diffusion Autoencoder 的类条件合成胸部 CT 生成框架,在公开的 RSNA 2020 肺栓塞(PE)数据集上训练,并通过潜在空间最近邻距离过滤拒绝过近样本以降低复现真实患者数据的风险。

正文 · 原文

Authors:Johannes B. Thalhammer, Kacper Ogórek, Tina Dorosti, Sebastian Peterhansl, Daniel Frey, Zijin Huang, Theresa Hiu, Tobias Lasser, Daniela Pfeiffer, Franz Pfeiffer, Florian Schaff

View PDF HTML (experimental)

Abstract:Large, well-annotated datasets are essential for developing medical artificial intelligence models, yet data sharing is often restricted by privacy regulations. Synthetic images may help address this limitation if they preserve diagnostic information while reducing the risk of reproducing patient data. We developed a diffusion autoencoder-based framework for class-conditional synthetic chest CT generation that incorporates latent-space distance filtering to reduce the likelihood of regenerating training samples.
A diffusion autoencoder was trained on the public RSNA 2020 Pulmonary Embolism (PE) dataset. PE-positive and PE-negative images were synthesized by sampling latent representations from class-specific kernel density estimates. Samples with a nearest-neighbor latent-space distance below a predefined threshold were rejected. To assess diagnostic utility, ResNet-50 classifiers were trained across 10 independent runs using real, synthetic, or mixed real-synthetic datasets. Performance was evaluated on a held-out real test set using the area under the receiver operating characteristic curve (AUC), with DeLong 95% confidence intervals (CIs).
Models trained on synthetic data achieved an AUC of 0.862 (95% CI, 0.851-0.874), only slightly lower than models trained on real data (AUC = 0.872, 95% CI, 0.861-0.883) and mixed real-synthetic data (AUC = 0.865, 95% CI, 0.855-0.876). These differences were statistically significant (p < 0.05) but small in absolute terms. A nearest-neighbor copy-detection analysis of 38,000 synthetic slices found no direct copies of real training images.
These findings indicate that the synthetic CT images preserve diagnostically meaningful information for image-level PE classification while incorporating measures intended to enhance privacy awareness and reduce similarity to real patient data.
Subjects: Image and Video Processing (eess.IV); Artificial Intelligence (cs.AI)
Cite as: arXiv:2611.33234 [eess.IV]
  (or arXiv:2611.33234v1 [eess.IV] for this version)
  https://doi.org/10.48550/arXiv.2611.33234

arXiv-issued DOI via DataCite (pending registration)

Submission history

From: Johannes Thalhammer [view email]
[v1] Tue, 24 Nov 2026 11:25:08 UTC (7,457 KB)

来源:arXiv cs.AI · arxiv.org